ADwin S7 PLC interface

Ethernet communication

The Simatic Fetch/Write communication via Ethernet network is a point-to-point connection between an ADwin system and a Simatic PLC. The connection enables write and read-only access to the system memory of the Simatic PLC. Access is available to data modules, flags, inputs, outputs, counters and timers.

The ADwin system is the client which runs the active communication. Seen from Simatic S7 the communication function is passive and only needs configuration. The PLC cannot access the ADwin system.

Requirements for access to a Simatic PLC:

  • ADwin system with Ethernet interface ENET2, current firmware and Bootloader option
  • Simatic PLC with Communication Processor (CP), which supports the Fetch/Write protocol
  • Two configured network connections on the PLC, one for Fetch and one for Write.

ADwin functions

In an ADbasic process a global parameter controls the communication with the PLC. The sent and received data, as well as the configuration data for communication, are stored in global arrays.

Parameters to be configured:

  • Array numbers for sent and received data
  • Number and start address of data to be transferred
  • Network configuration of the PLC: IP and port numbers
  • Type of system module (DB, flag, etc.)
  • TCP/IP timeout and polling time.

Download the ADwin Communication to Simatic PLC datasheet for more information.

Supported Simatic CPs

Generally, all CPs may be used which support the Fetch/Write protocol via TCP.

Simatic S7-300:

  • CP 343-1 Lean
  • CP 343-1 IT
  • CP 343-1
  • CP 343-1 Advanced
  • CP 343-1 PN.

Simatic S7-400:

  • CP 443-1
  • CP 443-1 Advanced
  • CP 443-1 IT.

What do our Customers say about us?

This was an excellent course which I feel sure will be extremely useful. I will certainly recommend the course to others. Tutor made the course very enjoyable. A born teacher – superb communicator

HP, Evesham, UK

Thanks also for your first class service, couldn’t ask for more, helped to fix an insurmountable problem for me really quickly and easily

PD, Aberdeen, UK

Thanks very much for all your time, it was really appreciated. As always Adept has been my number one company!

MA, Crawley, UK

I have now followed your (very clear!) instructions and am happy to report that my problem is solved. Magic! You have made me a much, much happier person!

CS, Reading, UK

For the time being we are unable to offer the following product ranges although we are currently working hard to increase the number of products we can offer in the future. Please contact us to talk about alternative products that we may be able to offer you.