| Design and Specifications
Graphical
Designer
Visual tool for creating full screen user interface designs.
Device
Configuration
Measurement device configuration and communications diagnostics
Help
Editor
Create context-sensitive help and SOPs.
NWA Quality
Monitor provides SQC charts for all types of measurementswhether
variable or attributein one package. The software offers the
same chart-generating capabilities as our award-winning NWA Quality
Analyst, producing all standard SQC/SPC charts and reports.
Variable
Control Charts
- X-bar
- Range
- Standard
Deviation
- Individual
Measurements
- Moving
Average
|
- Median
- Median/Individual
Measurements
- Cumulative Sum
(CUSUM)
- Exponentially
Weighted Moving Average (EWMA)
|
Attribute
Control Charts
- Percent
Defective (p)
- Number Defective
(np)
- Defects
(c)
- Defects
per Unit (u)
Short Run
Analysis (for all charts)
Pareto Analysis
Process Capability
Analysis
Select one
of eight distribution types:
- Normal
- Skewness
and Kurtosis Adjusted (Johnson)
- Two Parameter
Log normal
- Three Parameter
Log normal
- Truncated
Normal
- Folded Normal
- Weibull
- Rayleigh
User
Interface Components
User Interface
can be composed of any number and combination of components
- Input Box
- Key entry
- Measurement
device input
- Display
Box
- Calculations
- Informational
data
- Tabulate
Box - simplifies defect category entry
- Combo Box
- drop-down selection list
- Input Prompt
- specific to each Input Box
- Label Text
- full font and colour control
- Picture
- supports BMP, GIF, JPG, and PNG formats
- Command
Bar - dockable groups of command buttons
- Pop-up Menu
- cascading groups of command buttons
- Action Button
- individual command button
- Alarm Indicators
- alarms linked to each input and display box
- Alarm List
- displays current alarms
Data
Input Options
Input source
and management features
- Source
- Keyboard
entry
- Read from
measurement device
- Read from
barcode
- Calculation
result from defined formula
- Constant
value
- Incrementing
or sequence count
- Default
to previous value
- System
date - system clock
- System
time - system clock
- Upper and
Lower Bound limits
- Allow/Prevent
modification of existing data
- Input Mask
for key, device, and calculation input
- Field-specific
prompt text
- Field-specific
help reference
User
Commands
Command
Bar, Pop-up Menu, and Action Button options
- Command
bars dock to any margin
- Pop-up menus
cascade to 10 levels
- Button text
includes full font and color control
- Button definition
includes short-cut (function) keys
- Command
Actions
- Display
Chart - display SPC charts
- Print
Chart - print SPC charts
- Help -
display field-specific help
- Alarms
- display alarm lists
- Run -
start Quality Analyst automation script
- Send -
send pre-defined commands to devices
- Launch
- start other Windows applications
- Archive
- manually start data archive
Help
System
Complete
SOP support on the plant floor
- Context
sensitive help for each input field
- Full font
and colour control
- Embedded
graphics and pictures
- Includes
built-in Help file editor
- Reads RTF
file format from word processors and editors
Alarm
System
Visual and
audible alarming on specifications and SPC limits
- Alarm Types
- Specifications
- SPC Limits
- control and warning
- Fixed
Limits
- Alarm Indicators
- Separate
indicators for each alarm type
- Specific
to each Input and Display field
- Alarm Lists
- Fully
definable text for each alarm type
- Pop-up
or continuous display
- Includes
complete alarm history for each data record
- Alarm actions
- Add message
to alarm list
- System
beep
- Assign
text comment to data field
Device
Interface
Real-time
data collection from measurement devices
- Interfaces
through standard RS-232 (serial) ports
- Simple point-and-click
device definition
- Interfaces
with common measurement devices
- Scales
- Gages
- Multiplexers
- Special
Purpose
- Includes
extensive library of predefined devices
- Device configuration
and troubleshooting tool
- Troubleshoot
communications problems
- Test input
devices
Data
Storage & Connectivity
- Uses NWA
Quality Analyst Data Sets
- Allows up
to 200 characteristics per Data Set
- Includes
any combination of variable, attribute, or descriptive data
- Automatically
writes to ODBC-compliant databases; e.g., SQL Server, Oracle,
MS Access, etc.
Configuration
and Licensing
- NWA Quality
Analyst required for Data Set definition and SPC chart configuration
- NWA Quality
Monitor Designer (screen design, device configuration, help) to
configure plant-floor workstations
- NWA Quality
Monitor Runtime installs on each plant-floor workstation
System
Requirements
- Windows
95, 98, 2000, Me, NT4
- Any PC-based
LAN (NT, Novell, etc.)
Recommended
minimum systems:
- Quality
Monitor Designer:
266 MHz Pentium,
32 MB RAM
- Quality
Monitor Plant-floor Workstations:
120 MHz Pentium,
16 MB RAM
Note: Existing 486 and slower
Pentium systems may be used for plant-floor workstations, depending
on size and complexity of data input screens.
|