Adept Scientific - English
The world's best software and hardware for research, science and engineering.
flag arrow
clearclear

 Adept Store | register Join My Adept | Flags  
Adept Scientific | Amor Way | Letchworth Garden City | Herts | SG6 1ZA | Tel: +44 (0)1462 480055  
UKdedksvnofi
Home
Products
Training
Events
 Buy Online
Downloads
Academic Discounts
Support
My Adept
International |  About Us |  Adept Scientific Blog |  Contact Us |  Press Room |  Jobs
Adept Scientific on Facebook Adept Scientific on Twitter Adept Scientific on YouBube Adept Scientific on LinkedIn


The Next Steps

• Ask us a question
• Buy NWA Quality Analyst
• Find out about Training
• Sign up for a Webinar
• Download a Brochure
• Request a Brochure
• Download a Product Tour
• Download a Demo
• Meet Our Team
• Read our RSS Feeds

Learn More

Quality Analyst Home
Specifications
Database Connectivity
Cpk and DPMO reports
Rave Reviews
System Requirements

NWA Product Line
Overview

Focus EMI
  • KnowledgeBase
  • Collaboration
  • Implementations
Quality Information System
Quality Analyst
Add-on modules

NWA MvSPC™
NWA Stability Analytics™
Quality Analyst
WebServer

Embedded SPC

Latest Information

What's New in Version 6.3
Case Studies
Frequently Asked
Questions

Current Product
Release Numbers


Service & Support

Patches & Downloads
Tech Notes
Search the Knowledge
Base

Technical Support request

NWA Quality Analyst

NWA Quality Analyst 6.3
NWA Quality Analyst 6.3
NWA Quality Analyst 6.3
NWA Quality Analyst 6.3
NWA Quality Analyst 6.3
 
 
 

What's New in NWA Quality Analyst 6.3

NWA Quality Analyst 6.3® incorporates twelve extensions to the analytics and reporting capabilities. These result from the development of NWA Focus EMI® and enable Quality Analyst to deliver a richer Enterprise Manufacturing Intelligence (EMI) analytics and reporting feature set.

New Features

  • SPC Pattern Rules Selectable by Variable
  • Additional Sets of Specifications
  • Added Actions for Warning and Inner Limits
  • Out-of-Spec Plotting Characters for SPC Charts
  • Showing Tagged Data on SPC Charts
  • "Data Brushing" on SPC Charts and Other Graphics
  • Graphics X and Y “Zoom”
  • Bivariate Scatter Plots for Multivariate SPC Charts
  • “First N Rows” Range for File, Display, and Recalculation
  • Improved Control Chart Parameters dialog
  • New Histogram, Capability Report, and Boxplot Statistics
  • New Exception Report Statistics

1. SPC Pattern Rules Selectable by Variable

The pattern rules that are applied to control charts can now be selected for each variable. Previously they were selected globally and could only be set to on or off by each variable. The rules must already be defined in Quality Analyst “Settings”. This allows analytics to be tailored to individual process variables for real-time and EMI applications.

2. Additional Sets of Specifications

In addition to defining Upper (UCL) and Lower (LCL) Specification and Target values for each variable, up to 10 additional sets of specifications may now be set for each variable. The specifications, specification violations, and capability indices are displayed on the histogram, capability report, and exception report. The specifications may be enabled or disabled as desired. The additional specifications can be useful when multiple specifications are used for different purposes, such as for different customers or different stages of manufacturing and packaging.

3. Added Actions for Warning and Inner Limits

Points that violate Warning and Inner limits can now be highlighted with unique plotting characters on SPC Charts, appear on Exception Reports and are now listed in the graphic .NWG files that can be used by other NWA software. This provides more flexible analytics for exception reports, real-time reporting and EMI applications.

4. Out-of-Spec Plotting Characters for SPC Charts

Measurements that violate the upper or lower specification limits can now be identified on SPC Charts with an alternative plotting character and color. This feature is available only with the primary specification limits. This is designed to provide more flexible analytics and visualization for normal SPC reporting and real-time/EMI applications.

5. Showing Tagged Data on SPC Charts

Tagged data can now be shown on control charts while being excluded from control limit calculations and statistical analysis. The tagged points are plotted separately with a unique symbol and color, and are not connected with a line to the untagged data. These "ghost" points are not included in the SPC data (not connected by the data line) and are not used in calculations.

6. "Data Brushing" on SPC Charts and Other Graphics

Points common to the same Data Set record can now be highlighted on different charts with a technique known as "Data Brushing". When SPC Charts, Scatter Plots, Run Charts, or Normal Probability Plots are created using the same Data Set, points selected on one chart will be “brushed” on other charts to highlight points from the same Data Set row. "Brushed" points are circled, with two colors available.

7. Graphics X and Y 'Zoom'

Selected graphics types can now be zoomed on both the X and Y axis direction. The enhanced zoom works with the Scatter Plot, Normal Probability Plot, and Run Charts. This was added as a general improvement for MvSPC and is available for other graphics.

8. Bivariate Scatter Plots for Multivariate SPC Charts

Bivariate scatter plots with a 95% confidence bound and specification limits can be generated when using multivariate models. The bivariate scatter plot can be created from the QA Data or in a RUN file with the BIVARIATE command. If a Multivariate SPC chart (T-squared or SPE) is displayed, bivariate plots can also be generated directly from a variable contribution Pareto. Double clicking on a Multivariate Chart point displays the Contributions Pareto and right clicking on the Pareto selects and compares the top two or top three contributing variables. One or three bivariate scatter plots will be displayed depending on the selection.

9. “First N Rows” Range for File, Display and Recalculation

A “First N Rows” data range is now available for File-wide and Variable ranges. Like the “Last N Rows” range, the new range is always based on the current Data Set rows.

10. Control Chart Parameters dialogue improved

The Control Chart Parameters “Chart Type” now defaults to the "Individuals" chart for type “I” data (instead of "X-bar"). Also, changing the selected Variable no longer changes the selected Chart Type.

11. New Histogram, Capability Report and Boxplot Statistics

New statistics are available for Histograms, Capability Reports, and Boxplots.

  • Sum
  • Count below LSL
  • Count above USL
  • Count outside specifications
  • Estimated ppm (parts per million) below LSL
  • Estimated ppm above USL
  • Estimated ppm outside specifications
  • Actual ppm below LSL
  • Actual ppm above USL
  • Actual ppm outside specifications
  • Additional specification ID

12. New Exception Report Statistics

The exception report has a new 'count' and 'percent out-of-control' summary for each chart. If you would like to arrange a pilot or trial installation of our SPC software then please contact your local Adept Scientific office or email quality@adeptscience.com.

 

 


Ready to buy?

Every customer requirement for the NWA suite of products is unique and we offer pre-sales support to ensure your purchase fully meets the project requirements.

For more information about licencing and to discuss your SPC project contact our NWA team at your local office.

We also offer a consultancy service to assist you whether you're planning to implement SPC, starting out on a new quality initiative, or reviewing the outcome of recent quality projects.

Download our Consultancy Information Pack to find out more or contact your local office.

Featured Downloads

SPC Casebook: Three Valleys Water
SPC Casebook: Crompton Technology wind up flight control with NWA
SPC Casebook: The Welsh Blood Service Improves Quality with SPC

Latest Downloads

NWA Quality Analyst 6.3 Datasheet
NWA Quality Analyst 6.3 Evaluation Kit
Case Study: NWA Quality Analyst Supports Nuclear and Environmental Analysis Work
NWA Case Study - Cask of thousands
Quality Analyst Multivariate SPC datasheet

Latest News

SPC Casebook: Testing Waters with NWA Quality Analyst
Case Study: NWA Quality Analyst Supports Nuclear and Environmental Analysis Work
NWA Case Study - Cask of thousands
Reach your target weight using SPC
"NWA Quality Analyst allows us to...
adept

Top of the Page

Popular Links: ChemDraw | ChemOffice | Data Acquisition | Data Analysis | EndNote | Mathcad | MathType | Quality Analyst | Reference Manager | VisSim

EU ePrivacy Directive | Our Privacy and Terms and Conditions Statement
All Trademarks Recognised. Copyright © 2013, Adept Scientific Ltd.
Site designed and maintained by Lyndon Ash

Adept Scientific | Amor Way | Letchworth Garden City | Herts | SG6 1ZA | Tel: +44 (0)1462 480055