Price: £ 875.00
Availability: Usually dispatched within 1 working day
This item qualifies for FREE DELIVERY (UK mainland ONLINE orders only).
Click Here to download the DataShuttle USB/50 Series Guide.
Highlights
- USB connection to the PC : no extra power supplies or batteries required
- Convenient removable screw-terminal signal connections
- High-resolution 22-bit A/D converter
- Built-in cold junction compensation for direct thermocouple measurements
- 500V isolation protects your PC and provides low-noise thermocouple and voltage measurements
- Full-scale voltage inputs up to ±20V
- Frequency/pulse measurements up to 1 MHz
- Digital I/O with high-voltage and current sink capability for direct drive applications
- Expandable up to 80 channels of analogue and digital I/O
- Digital calibration : no potentiometers or adjustments required
Description
- Isolation: 500 VDC from PC common
- Power Requirements: Powered from USB, or from external +6 to +16 VDC (AC supply included)
- Environmental: 0 C to 50 C, 0-95% RH (non-condensing)
- Dimensions: 182 mm W x 92 mm D x 45 mm H (7.1 in x 3.6 in x 1.8 in)
ANALOGUE SPECIFICATIONS
- Each channel is configurable for single-ended or differential; volts or thermocouple inputs
- DataShuttle USB 55: 10 single-ended, 5 differential; volts or TC channels
- DataShuttle USB 56: 20 single-ended, 10 differential; volts or TC channels
- Input Voltage Range: Sixteen software-programmable ranges, from ±20V full scale to ±30 mV full scale
- Thermocouple Type: J, K, T, E, R, S, B, N14G, N28G
- Thermocouple Accuracy: ±0.5 C
- Over-Voltage Protection: ±45V relative to analog common
- AC Common Mode Rejection: >120 dB @ 50/60 Hz
- Channel-to-Channel Crosstalk: <-110 dB (DC to 100 Hz; up to 10K Ohm source resistance)
- Accuracy: 0.01% of reading, +0.002% of range (exclusive of noise)
- Input Resistance: 10M Ohm (SE), 20M Ohm (DE)
- Bias Current: <1nA (0 C to 35 C)
- Cold-Junction Accuracy: ±0.5 C (15 C to 35 C)
- Measurement Speed: Each channel can have independent measurement duration and resolution; channels can be programmed to be scanned in any order
- Resolution/Speed (10 channel scan): 22 bit, 3 samples/s; 21 bit, 8 samples/s; 19 bit, 25 samples/s; 17 bit, 48 samples/s; 15 bit, 80 samples/s (57 samples/s for thermocouples)
FREQUENCY MEASUREMENTS
- DataShuttle USB 55: 2 frequency/pulse input channels
- DataShuttle USB 56: 4 frequency/pulse input channels
- Operating Modes: Pulse count (totalise), frequency, and duty cycle
- Frequency Response: DC to 1 MHz
- Input Range: ±15V absolute maximum, <1.3V (low), >3.8V (high)
- Pull-up Resistor: 27K Ohm to +5V for switch or relay sensing
- Debouncing: None, 0.8, 3.2, or 13 msec (software selectable)
- Totalise: Up to 2^32 counts/scan
- Frequency Resolution: Up to 7 digits, user-selectable
DIGITAL I/O
- Each I/O line is individually programmable as input or output
- Each I/O line includes an open-collector driver with a 27K Ohm pull-up resistor to +5V for output, and a Schmitt-trigger input buffer
- DataShuttle USB 55: 8 digital I/O lines
- DataShuttle USB 56: 16 digital I/O lines
- Over-Voltage: +20V for up to 1 minute
- Output:
- Voltage Range: 0 to +5V with no external pull-up resistor; 0 to +15V with external pull-up
- Maximum Sink Current: 150 mA/output continuous, 500 mA output peak (<100 µs), 150 mA total continuous (per bank of 8 outputs)
- Output Resistance: 10 Ohms max
- Output Updates: Outputs may be changed via program control
- Input:
- Voltage Range: 0 to +15V
- Thresholds: <1.3V (low), >3.8V (high)
INCLUDED WITH PRODUCT
Each DataShuttle/USB ships with a 1m USB cable (CA-179-1), DaqView software and drivers for Visual Basic, Delphi and C++ for Windows, DASYLab and LabVIEW drivers, and an auxiliary AC power supply.
OPTIONS
- Analogue/Digital Expansion Module - PDQ1
- Analogue Expansion Module - PDQ2
- DIN Rail Mounting Adapter - PDQ10
- 4-Port Powered Hub - PDQ11
- USB 16 ft Extender Cable - PDQ12
- PCI to Dual USB Card - PDQ13
Software
Personal DaqView, spreadsheet-style software for Out-of-the-Box setup, acquisition, and real-time display
PostView for post-acquisition data viewing
Support for Visual Basic@reg;, C/C++, LabVIEW®, and DASYLab®
|
 |
 |
 |
|