If you are a user of a software or hardware product purchased from Adept Scientific and require technical support, please use our Technical Knowledge Base below. If you can't find a solution on the Knowledge Base then please complete our technical support form or contact us by email or by telephone on +44 (0) 203 695 7810

Results 1 - 10 - 13. Next ›

Understanding the digital IO functions for the USB-1208LS and USB-1208FS
A The USB-1208FS and USB-1208LS support two types of function for Digital Input\Output. 1) Port Functions The digital functions that write, read or configure ports (groups of 4 or 8 bits) are cbDOut, cbDIn and cbDConfigPort. In the arguments to these functions, the 8255 chip is divided into two 8 ....

Data Acquisition > USB
 
 

I get an rrror when using USB-1208FS with XAIN.vi LabVIEW example program.
2 The user has the wrong range selected in LabVIEW. When in SE mode, the 1208 modules only have a +/- 10V range, and the LabVIEW example program defaults to +/-5V. Error Messages USB All All en All....

Data Acquisition > USB
 
 

What is the Board Number of each device?
6 The board number is assigned by Instacal to each Measurement Computing board installed on the PC. It is not the same as the board serial number, as it is recorded only in the CB.CFG configuration file created by Instacal. The Universal Library requires you to specify the board number in each funct....

Data Acquisition > USB
 
 

USB-500 error: "The application failed to initialise properly (0xc000135). Click OK to terminate the application" appears when the software is opened.
E USB-500 software requires the latest .NET framework for the Operating System to be installed. This should be included on the CD shipped with the device. It may be that there is a problem with the installation and it needs to be reinstalled. It is possible to check whether .NET framework is instal....

Data Acquisition > USB
 
 

DASYLab error: Background operation already in progress
6 These devices have no support for concurrent clocked operations on A/D and D/A. This means that after an analog input or output object has been started, you will not be able to perform other analog or digital I/O operations. Clocked A/D is supported with software paced D/A, but not visa-versa. So....

Data Acquisition > USB
 
 

Version 2.5 of the MATLAB Data Acquisition Toolbox supports the PMD-1024LS, PMD-1608FS, PMD-1208LS
Version 2.5 of the MATLAB Data Acquisition Toolbox supports the PMD-1024LS, PMD-1608FS, PMD-1208LS Yes. Customers need to use version 2.5 of the MatLab Data Acquisition Toolbox. See the link below for a full list of MCC hardware supported by the MatLab Data Acquisition Toolbox. http://www.mathwork....

Data Acquisition > USB
 
 

Labview examples for USB-TEMP/TC
These examples use the TIn and TInScan VIs to read temperatures from the USB-TEMP or USB-TC. Please save all the attached files to a folder and run the example VIs from the local folder. All USB All en....

Data Acquisition > USB
 
 

How do I get access to the calibration (CAL) voltage on the PMD-1208FS or PMD-1608FS?
In Non .NET environments To turn on CAL: cbSetConfig(BOARDINFO, baordNum, 0, BICALOUTPUT, 1); To turn off CAL: cbSetConfig(BOARDINFO, boardNum, 0, BICALOUTPUT, 0); Tested Boards. Approximate Voltage Values PMD-1208FS 0V 2.5V PMD-1608FS 0V 0.619V This function should not be used with th....

Data Acquisition > USB
 
 

When using a PMD1208LS device do I need to connect all Analogue GND's (3,6,9,12), as well as Port A GND (29), Port B GND (40), Pin 31 GND and Analogue Out GND (15)?
You do not need to connect all the analog ground pins. Each analog ground pin is connected to the same place internally. There is only one unique ground on the PMD-1208LS. There are not separate analog and digital grounds. (This is not true of some other devices, for example the PMD-1208FS.) Hence....

Data Acquisition > USB
 
 

Das Wizard updated support for 0-4V range (PMD-1208FS Analog Output)
Das Wizard updated support for 0-4V range (PMD-1208FS Analog Output) Download the updated daswiz.dll file below. Close Excel and copy the updated daswiz.dll to the Das Wizard installation folder. This is by default: C:\Program Files\Das Wizard\ Restart Excel. The 0-4 range is now available. USB ....