If you are a user of a software or hardware product purchased from Adept Scientific and require technical support, please use our Technical Knowledge Base below. If you can't find a solution on the Knowledge Base then please complete our technical support form or contact us by email or by telephone on +44 (0) 203 695 7810

Results 11 - 20 - 20. ‹ Previous |

Accessing the +/- 5V range of the PMD-1608FS from DASYLab 8.0.
Accessing the +/- 5V range of the PMD-1608FS from DASYLab 8.0. Problem Using the PMD-1608FS and DASYLab 8.0, the drop down list box does not show the +/- 5V range. Solution A driver update is required. Instructions 1) Close DASYLab 8.0. 2) Download the attached MCBN.DLL and save it to the DASYLab i....

Data Acquisition > Measurement Computing
 
 

Single Ended and Differential Configuration.
Single Ended and Differential Configuration. The attached document explains Differential mode and Single Ended configuration, when to use either mode, and how to connect your input circuit using either mode. The document covers: Voltage Input - Single Ended Voltage Input - Differential Current Inpu....

Data Acquisition > Measurement Computing
 
 

HPVEE: Counter on the PCI A/D boards
The PCI-DAS1602 and PCI-DAS1200 series boards have two counter timer chips. The chip first has counters 1 to 3 all assigned to internal pacing!! Hence the first available is counter 4. Within HP-VEE and ULCT01 - for instance, use Counter 4 and also Load register as 4. The program will count down f....

Data Acquisition > Measurement Computing
 
 

Linux support for Rocketport cards is available by download
Linux support for Rocketport cards is available FOC by download from: http://rocketport.sourceforge.net/ MeasurementComputing na en....

Data Acquisition > Measurement Computing
 
 

Notebook PC Power Management can cause problems
Notebook PC Power Management can cause problems with data acquisition For example, if a ComputerBoards Universal Library cbAInScan continuous+background with a PCM-DAS16 hangs for no apparent reason - after taking data successfully for tens of seconds, then it may be that a conflict with the PC's p....

Data Acquisition > Measurement Computing
 
 

Analogue Cable and Terminal Panel Guide
MeasurementComputing n/a en....

Data Acquisition > Measurement Computing
 
 

QUAD card filter can default to
If you are getting incorrect count results from the quadrature signal at higher speeds, say 400KHz, but correct results at lower speeds, say 140KHz, you may need to change the setting of the onboard filter. Case Study: By using cbCLoad32(BoardNum, PRESCALER1, 1) the low pass digital filter was set....

Data Acquisition > Measurement Computing
 
 

Using PCM-DAS16S/12 with EXP16, ISO-RACK16 or BNC16SE
The PCM-DAS16S/12 or PCM-DAS16S/16 can be used with EXP16, ISO-RACK16 or BNC16SE by connecting with cable PCM-CD16S/EXP16. MeasurementComputing na en....

Data Acquisition > Measurement Computing
 
 

How do I install Instacal from CD on a PC without a CD drive ?
Within the folder Product on the Instacal CD there is a separate folder for each floppy disk image. Copy the contents of each folder to a separate floppy disk and then install from these. MeasurementComputing 5.02 en....

Data Acquisition > Measurement Computing
 
 