Results 1 - 10 - 20.
Next»»
|

Date Modified
|
Error number 308 has no text when running Instacal.
A Check for duplicate copies of CBW32.DLL on the PC by searching the entire hard drive, including system and hidden files, for files of this name. There should only be one copy, in the main Instacal installation folder (typically C:\program files\Measurement Computing\daq\ or C:\MCC on older systems....
What is the Board Number of each device?
6 The board number is assigned by Instacal to each Measurement Computing board installed on the PC. It is not the same as the board serial number, as it is recorded only in the CB.CFG configuration file created by Instacal. The Universal Library requires you to specify the board number in each funct....
How do I emulate hardware using Instacal? I need to develop software but I do not have the Measurement Computing hardware on the development machine.
2 It is possible to install a "Demo board" in Instacal, which provides emulation of Analog Input and Digital I/O. The Demo board is installed by default, but if it has been removed you can install it as follows: To install the demo board, run Instacal, click the "+" button on the left end of the too....
Im new to LabVIEW, and want to use one of the Measurement Computing data acquisition boards. What do I need? And where do I start?
6 To use any data acquisition hardware products with LabVIEW, youll need to download the MCC DAQ CD which contains driver software for each device, along with the Universal Library for LabVIEW. There are 2 versions of the Universal Library that install seamlessly with LabVIEW. Which version required....
Instacal detects my hardware, but my Universal Library application returns Error 1 "Invalid Board Number".
E Check that you have set the correct board number in the application, and that it corresponds to the board number assigned in Instacal. If checking the board number does not reveal a solution, this problem can also be caused by additional copies of CBW32.DLL on your hard disk. Search your hard driv....
MCC-DAQ Error Message Possibly reason - Invalid counter device
E PCI-DAS100 counter module in DASYLab gives an error message: " Invalid counter device" The PCI-DAS1000 has six counter channels: Channels 0, 1, and 2 are not available to the user; they are used by the A/D circuitry.. Channels 4, 5, and 6 are available to the user. The customer needs to manu....
Where can I find hardware register maps for Measurement Computing boards?
2 Where can I find hardware register maps for Measurement Computing boards? Some boards contain hardware register maps in a section of the manual. This is particularly true of the older ISA boards. Board manuals can be downloaded at the link below. http://www.measurementcomputing.com/manuals.html Ha....
Measurement Computing PCMCIA bus
E PCMCIA bus on MCC's PCMCIA cards is 16 bits All MCC PCMCIA cards: - Are of the same physical size and bus structure. - Have a 16 bit bus and are Type II cards (i.e. up to 5.5 mm thick) so that they fit into Type II and Type III PCMCIA slot. - Require 5V power from the bus (sometimes the bus on ne....
Version 2.5 of the MATLAB Data Acquisition Toolbox supports the PMD-1024LS, PMD-1608FS, PMD-1208LS
Version 2.5 of the MATLAB Data Acquisition Toolbox supports the PMD-1024LS, PMD-1608FS, PMD-1208LS Yes. Customers need to use version 2.5 of the MatLab Data Acquisition Toolbox. See the link below for a full list of MCC hardware supported by the MatLab Data Acquisition Toolbox. http://www.mathwork....
PWM with Measurement Computing Counter cards and Universal Library
PWM with Measurement Computing Counter cards and Universal Library We have implemented a PWM control using Universal Library controlling the 8254 counter chip on a PCI-DAS1200. You should be able to do the same using Softwire or Universal Library and any MCC board with a 8254 counter with three us....
|